Quick Answer: How Many Amps Does A 10 Hp Electric Motor Draw?

How many amps is a 11kW motor?

Fixed mains supply output is 11kW (15HP) x 1460RPM at 400V x 50Hz 3ph.

Full Load Current – 22.5A at 400V.

Power Factor is 0.80 when mains connected at 50Hz..

How many watts does a 5 hp motor use?

Watts to horsepower conversion tableWatts (W)Mechanic horsepower (hp(I))Metric horsepower (hp(M))5 W0.006705 hp0.006798 hp6 W0.008046 hp0.008158 hp7 W0.009387 hp0.009517 hp8 W0.010728 hp0.010877 hp28 more rows

What size breaker do I need for a 3 HP motor?

A 20 amp breaker is all you’d ever need for a 220v 3HP motor. It wouldn’t hurt anything to run 30amp circuits if you so choose, but it’s overkill.

How many kW is a 3hp motor?

Horsepower (metric) to Kilowatt Conversion TableHorsepower (metric)Kilowatt [kW]1 horsepower (metric)0.73549875 kW2 horsepower (metric)1.4709975 kW3 horsepower (metric)2.20649625 kW5 horsepower (metric)3.67749375 kW7 more rows

How many amps is a 40 hp motor?

AC Motor Full Load AmperesHP200 Volts440-480 Volts2578.2343092404012052501506523 more rows

How many amps does a 1 HP pool pump draw?

12 AmpsSince it’s an aboveground pool pump it’s an uprated model and draws in the vicinity of 10 to 12 Amps at 120 volts.

How do you convert HP to amps?

Converting horsepower to amps can be done in a few simple steps, or using this simple formula.Amps = (Horsepower × 746) ÷ Efficiency ÷ Volts.Watts = Horsepower × 746.Watts = WattsηAmps = Watts ÷ Volts.Amps = HP × 746V × η × PF.

How much electricity does a 5 hp motor use?

Therefore, the power consumed by a 5 HP motor performing at 80% efficiency will be: Output mechanical energy: 5 HP X 746 Watts = 3,730 Watts or 3.73 kW. As the output mechanical energy is the result of the motor performing at 80% efficiency, the power consumed by the 5 HP motor will be 3.73 kW X 100 ÷ 80= 4.66 kW.

How do I know what size breaker to use?

The general rule of thumb is that circuit breaker size should be 125% of the ampacity of cable and wire or the circuit which has to be protected by the CB. Let see the following solved examples: Example 1: Suppose, a 12 gauge wire is used for 20 amperes lighting circuit having 120V single phase supply.

What size breaker do I need for a 5 hp motor?

60 ampIn fact code recommends a 60 amp circuit breaker for a 5 hp 230v motor, but with overload protection.

What size breaker do I need for a 50 hp motor?

Electrical motor wiring data – NEMA amps, starter size, HMCP size for motors ranging 1/2 to 500 hpMotor HPNEMA ampsMotor Circuit Protector type HMCP (ampere)405210050651006077150759615016 more rows

What size breaker do I need for a 2 hp motor?

How to Calculate How What Size Circuit Breaker a Machine will Need:HorsePower of Main Motor220 Volts, 1 phase220 Volts, 3 phase1 Hp5.6 Amps2.8211.25.6316.88.4422.411.211 more rows

How many amps is a 1 hp motor?

AMP DRAW BASED ON HORSEPOWERHP1 Phase Amps3 Phase Amps115 volt230 volt1/29.82.23/413.83.21164.212 more rows•May 21, 2020

What is the full load current of a 1 hp motor?

Three Phase MotorsMOTOR RATINGHPAPPROX. F.L.C. AT LINE VOLTAGE0.56 kW3/43.10.75 kW13.51.1 kW1.551.5 kW26.427 more rows•Mar 5, 2021

How many amps does a 1 HP 3 phase motor draw?

Here are the Full Load Amp (FLA) values for typical 230VAC and 480VAC 3 phase motors.Motor horsepowerFull load amps 230VACFull load amps 460VAC13.31.71.54.72.4263.0394.517 more rows•Apr 1, 2017

How many watts does a 10 hp motor use?

7680 wattsThere 746 watts for every 1 horse power. So a 10 hp motor will need 7680 watts when operating. In one hour the motor will consume 7.680 KWatt hours. If the units are charged at 10 cents each then then that equates to 10x 7.680 / 100 Dollars = 76.8 cents.

How many watts does a 1hp motor use?

ELECTRIC MOTOR WATTAGE GUIDEMotor Rating HPApproximate Running WattsUniversal Motors Small Appliance1/34506001/26007503/485010001100012506 more rows

What size wire do I need for a 1 hp motor?

Single Phase (230 Volt) – Wire Size Selection Guide*HPCable Length114121 1/21412214124 more rows

What size breaker do I need for a 7.5 hp motor?

Re: Wire and breaker size for 7.5 hp motor You need 50 amp rated wire with a 50-100 amp breaker.

What size breaker do I need for a 15 amp motor?

Re: Correct breaker size for 15A compressor? Use a 12 wire and a 20A breaker. 15A ends are allowed on 20A circuits.

What size breaker do I need for a 10 hp motor?

Full Load Current: Three Phase AC MotorsMotor HorsepowerSize Breaker7-1/2230V 460V40 3010230V 460V50 3015230V 460V70 4020230V 460V100 506 more rows•Feb 16, 2017